Development kit for DATAMAN 570 Programmer’s Guide Inprise Delphi Version 1.00 Copyright © 2004-2008 Dataman
Development kit for DATAMAN 570 series Programmer’s Guide measurements, because the random nature of this process causes measurements with the same
Development kit for DATAMAN 570 series Programmer’s Guide 3. Reference Functions available in DK can be divided into five groups: Functions, that r
Development kit for DATAMAN 570 series Programmer’s Guide 3.1. Functions, that returns information about device 3.1.1. GetDKError In the case where
Development kit for DATAMAN 570 series Programmer’s Guide Parameters: - Return value: Device code is calculated as 571+return value. 3.1.4. GetDe
Development kit for DATAMAN 570 series Programmer’s Guide nsPerDiv – amount of nanoseconds per screen division (50 samples); this value is passed to
Development kit for DATAMAN 570 series Programmer’s Guide 3.2.2. InitHardware Initializes device. After successful call of this function, the device
Development kit for DATAMAN 570 series Programmer’s Guide mV – determines range, which is to be set (amount of mV per division) Return value: Th
Development kit for DATAMAN 570 series Programmer’s Guide Parameters: channel – determines channel CHANNEL_A – channel A CHANNEL_B – channel B
Development kit for DATAMAN 570 series Programmer’s Guide TRIGGER_MODE_AUTO – in case, that the trigger event doesn’t occur for longer time, the ac
Development kit for DATAMAN 570 series Programmer’s Guide 3.3.12. SetTriggerEdge Sets triggering on the selected edge (leading or trailing) on the s
Development kit for DATAMAN 570 series Programmer’s Guide Thank you for choosing the Dataman 520 Series Ocilloscope with development kit. We believe
Development kit for DATAMAN 570 series Programmer’s Guide size – length of memory used for data acquisition (valid values are: 1024, 2048, 4096, 819
Development kit for DATAMAN 570 series Programmer’s Guide ONOFF_ON – turns the digital shielding on level – determines the digital shielding fac
Development kit for DATAMAN 570 series Programmer’s Guide - 22 - channelB – amount of channel B, that was measured (percentage) Return value: -
Development kit for DATAMAN 570 series Programmer’s Guide Contents 1. Basic information...
Development kit for DATAMAN 570 series Programmer’s Guide 3.5. Other functions...
Development kit for DATAMAN 570 series Programmer’s Guide Figures and tables Table 1.1. –Development kit (DK) contents...
Development kit for DATAMAN 570 series Programmer’s Guide 1. Basic information 1.1. Development kit contents All development kit (DK) parts are loca
Development kit for DATAMAN 570 series Programmer’s Guide 2. Controlling the device 2.1. Device initialization First of all, it is necessary to load
Development kit for DATAMAN 570 series Programmer’s Guide data:array[0..1024*1024-1]of TSample; begin GetData(@data,@lng); 2.4. Acquired data all
Development kit for DATAMAN 570 series Programmer’s Guide 01d2d3d4d-1d-2d-3d-4dtUt1.2.3.4.5.6.7.8.9.10.5.7.1.4.8.3.2.10.9.6.5.7.1.4.8.3.2.10.9.6.5.7
Comments to this Manuals